VX 805 Out of Memory Error

Some VX 805 PIN pads loaded with XPI 8.42b may be shipped from distributors missing 2 parameters required for reliable operation. This can cause the PIN pad to display an “Out of Memory” or Verix debug message.

Follow the steps below to set these parameters manually from the PIN pad’s system menu.


  1. Press "F2" and "F4" to enter system mode.

    The password is "1 ALPHA ALPHA 6 6 8 3 1 Enter"

    Alpha is a black key located directly above the 2 key. Enter is the Green key
     

  2. Press "2" for Edit Parameters
     
  3. Press ENTER and select "1" for Group ID

    The password is "1 ALPHA ALPHA 6 6 8 3 1"
     

  4. Press ENTER to select CONFIG.SYS
     
  5. Press "1" for New
     
  6. For the parameter name, enter *DHEAP

    For the alpha characters, press the associated number key followed by ALPHA until the correct letter appears. * is located below the 7 key.
     

  7. Press ENTER to confirm the new parameter.
     
  8. For the value, enter 0.
     
  9. Press ENTER to confirm the new value.
     
  10. Press 1 for New again.
     
  11. For the parameter name, enter "#CZE". For the alpha characters, press the associated number key followed by ALPHA until the correct letter appears. 

    # is located below the 9 key.
     
  12. Press ENTER to confirm the new parameter.
     
  13. For the value, enter 1.
     
  14. Press ENTER to confirm the new value.
     
  15. Press CANCEL.
     
  16. Press 1 for “Restart”.